100 Delawanna Ave 07014 Clifton New Jersey, USA
Digital Realty (EWR20)

This facility is a robust, seven-story building encompassing 211,000 sq.ft. in total, with 179,000 sq.ft. currently leased to Telx. Its design incorporates resilience, as it is situated outside the 500-year flood plain and is located in Seismic Zone 2A. The structure features a membrane and reinforced concrete decking roof, with roof rights available, and can support a substantial floor loading of 200 lbs/sq.ft.

Power Infrastructure

The power specifications are designed for high availability and density. The total Utility Power Capacity is 33,000 kW. For critical load protection, the UPS Power Capacity is 4,000 kW, with a high level of N+1 redundancy. Standby power is provided by Generator Power Capacity of 6,750 kW, also featuring N+1 redundancy. The facility supports a high Power Density of 150 W/sq.ft.

Cooling and Redundancy

The cooling system maintains a high level of fault tolerance, operating with N+1 redundancy. The overall design focuses on ensuring continuous operation, with both UPS Redundancy and Standby Power Redundancy specified at N+1, matching the Cooling Redundancy of N+1.

Capacity and Services

The facility boasts a Fully Built-Out Power capacity of 3.9 MW and offers a substantial Fully Built-Out Whitespace of 143,500 sq.ft. Services available to tenants include Full Cabinets, Partial Cabinets, Shared Rackspace, Cages, Suites, Footprints, and Remote Hands support.

Connectivity

Connectivity is highly robust, featuring Diverse conduit entry points for fiber and building entry. The center hosts 2 Internet Exchange Points and facilitates connections to 20 Peering networks. Additionally, there are 4 tenants offering colocation services.

Security and Compliance

Security measures include 24x365 manned security, Biometric card key access control, Digital video monitoring and recording, and CCTV surveillance. The facility is compliant with SSAE 16 SOC2, DSS PCI, ISO27001, ISO9001, ISO14001, SOC 2 Type II, and SOC 3 Type 2. Onsite Security and Technical Staff are available 24/7.

Operational Details

The building has 7 floors and a Total Building Size of 183,000 sq.ft. (note: this conflicts with the initial 211,000 sq.ft. figure). It began operation in 1971. Parking is available for staff and tenants. The maximum floor load is 200 lbs/sq.ft.

Why Choose Hudson County Dc 1

Hudson County Dc 1 data center is built to meet the demands of modern enterprises, offering robust infrastructure, premium connectivity, and top-tier security. Whether you're deploying a single server or scaling to multiple racks, each facility is engineered for performance, reliability, and flexibility.

Tier III Certified

Redundant infrastructure with 99.99% uptime guarantee

Premium Connectivity

Multiple carrier options and low-latency connections

Advanced Security

Biometric access, 24/7 monitoring, and CCTV surveillance

Prime Location

Central Hudson County location with excellent transport links

Expert Support

Local technical team available 24/7 for remote hands

Scalable Solutions

From single rack to private cage configurations

Technical Specifications

Comprehensive infrastructure details for Hudson County Dc 1

Total Critical Power

3.9 MW

Indicates the maximum uninterrupted power capacity the facility can support during operation.

UPS Redundancy

N+1

Ensures continuous power supply via redundant UPS systems in case of failure.

Standby Power Redundancy

N+1

Supports critical systems with backup power sources during outages or maintenance.

Cooling Redundancy

N+1

Maintains optimal temperatures through backup cooling systems.

CCTV Surveillance

Monitors premises in real-time for safety and compliance.

Biometric Access Control

Secures critical areas with fingerprint or retinal scanning systems.

Card Access Control

Allows controlled entry through RFID or magnetic access cards.

Onsite Security Staff

Ensures 24/7 monitoring by trained security personnel.

Total Whitespace

143,500 Sq.f.

Indicates available raised floor space for IT infrastructure.

Total Building Size

183,000 Sq.f.

Total structural area of the facility housing all infrastructure.

Roof Access

Facilitates maintenance or antenna installations on the roof.

Onsite Technical Staff

Certified technicians available on-site to assist with technical needs.

Key Performance Metrics

99.99%
Uptime SLA
3.9 MW
Total Power
24/7
Remote Hand Support

Compliance & Certifications

PCI DSS
PCI DSS
Certified
SOC 2
SOC 2
Type II Certified
SOC 3
SOC 3
Type II Certified
ISO 27001
ISO 27001
Information Security
ISO 9001
ISO 9001
Quality Management
ISO 14001
ISO 14001
Environmental Management

Our Colocation Plans

Want to get a custom quote?

Interested in this facility? Reach out to our team for specific pricing and availability.

contact us vector

Sales:

Take the first step and contact us. We begin every new conversation with a thorough vetting process to ensure we understand your needs and goals. This helps us align our products and services with your definition of success.

sales@colocationm.com