Datacenter Image
3401 Technology Drive 55811 Duluth Minnesota, USA
Ark Data Centers (Involta's)

Involta’s Duluth, Minnesota, data center is a world class colocation facility encompassing over 26,000 square feet of total building space. This LEED Silver certified building is designed as a Tier III capable facility, though it integrates several Tier IV characteristics for enhanced reliability. The core is protected by high-density, reinforced concrete walls, providing a purpose-built environment that allows organizations to bypass the massive capital expenses of building and maintaining their own private infrastructure.

Power Infrastructure and Redundancy

To ensure uninterrupted uptime, the facility features a robust power architecture including a 2N UPS redundancy configuration. The fully built out power capacity stands at 0.3 MW, supported by standby power redundancy (N). These systems ensure that critical data remains online even during external power failures, providing a level of reliability that meets the needs of enterprise level operations.

Environmental Controls and Cooling

Maintaining the longevity of hardware requires a strictly controlled climate. The Duluth facility utilizes an N+1 cooling redundancy system to manage temperature and humidity with precision. This redundant HVAC setup ensures that even if a cooling unit fails, the environmental conditions remain stable, preventing hardware from overheating and ensuring the whitespace accounting for 3,200 square feet of the facility remains optimal for server performance.

Connectivity and Network Reliability

Connectivity is a cornerstone of the Involta design, featuring a redundant fiber optic ring to prevent single points of failure in data transmission. The facility provides access to five peering networks, offering diverse routing options and highspeed throughput. Clients can choose from various deployment scales, including full or partial cabinets, shared rackspace, cages, and custom suite footprints to match their specific networking requirements.

Multi-Layered Security and Monitoring

Security is managed through a blend of physical barriers and advanced technology. The facility employs a mantrap entry, 24/7/365 CCTV surveillance, and onsite security staff available at all times. Access is strictly governed by dual-factor authentication, utilizing both card access and biometric security controls. This always-on monitoring ensures that only authorized personnel can enter the high-density core areas.

Compliance, Support, and Amenities

The Duluth data center is engineered to meet rigorous regulatory standards, including HIPAA, SOC 2 Type II, DSS PCI, and NIST 800-53 certifications. Beyond technical specifications, Involta offers Remote Hands services for onsite technical assistance, as well as professional amenities such as a conference room and breakroom for visiting technicians. The entire facility is also protected by an automatic fire suppression system to mitigate risk and ensure data integrity.

Our Colocation Plans

Data Center Server Racks

Why Choose Duluth Dc 1

Duluth Dc 1 data center is built to meet the demands of modern enterprises, offering robust infrastructure, premium connectivity, and top-tier security. Whether you're deploying a single server or scaling to multiple racks, each facility is engineered for performance, reliability, and flexibility.

Tier III Certified

Redundant infrastructure with 99.99% uptime guarantee

Premium Connectivity

Multiple carrier options and low-latency connections

Advanced Security

Biometric access, 24/7 monitoring, and CCTV surveillance

Prime Location

Central Duluth location with excellent transport links

Expert Support

Local technical team available 24/7 for remote hands

Scalable Solutions

From single rack to private cage configurations

Technical Specifications

Comprehensive infrastructure details for Duluth Dc 1

Total Critical Power

0.3 MW

Indicates the maximum uninterrupted power capacity the facility can support during operation.

UPS Redundancy

2N

Ensures continuous power supply via redundant UPS systems in case of failure.

Standby Power Redundancy

N

Supports critical systems with backup power sources during outages or maintenance.

Cooling Redundancy

N+1

Maintains optimal temperatures through backup cooling systems.

Automatic Firesuppression

Instantly detects and suppresses fires without manual intervention.

Mantrap Entry

Prevents unauthorized access with secure, two-stage entry points.

CCTV Surveillance

Monitors premises in real-time for safety and compliance.

Biometric Access Control

Secures critical areas with fingerprint or retinal scanning systems.

Card Access Control

Allows controlled entry through RFID or magnetic access cards.

Onsite Security Staff

Ensures 24/7 monitoring by trained security personnel.

Total Whitespace

3,200 Sq.f.

Indicates available raised floor space for IT infrastructure.

Total Building Size

6,000 Sq.f.

Total structural area of the facility housing all infrastructure.

Conference Room

Dedicated space for meetings, collaboration, and customer use.

Breakroom

Provides a relaxation area for staff and technicians.

Key Performance Metrics

99.99%
Uptime SLA
0.3 MW
Total Power
100%
Secure Monitoring

Compliance & Certifications

PCI DSS
PCI DSS
Compliant
SOC 2
SOC 2
Type II Certified
HIPAA
HIPAA
Health Privacy
NIST 800-53
NIST 800-53
Certified

Want to get a custom quote?

Interested in this facility? Reach out to our team for specific pricing and availability.

contact us vector

Sales:

Take the first step and contact us. We begin every new conversation with a thorough vetting process to ensure we understand your needs and goals. This helps us align our products and services with your definition of success.

sales@colocationm.com