Datacenter Image
5 Eskdale Rd, Winnersh Triangle RG41 6TS Wokingham United Kingdom
18.78 Miles to nearest airport
Csquare (London LHR3-A)

Cyxtera operates a robust portfolio of five interconnected data center campuses strategically positioned across London Docklands, Slough, and Reading. These sites are linked by direct low latency fiber routes, ensuring seamless data transfer and high speed connectivity. By distributing facilities across these key regions, Cyxtera provides a resilient infrastructure designed to support the intensive IT requirements of the Greater London Area while offering clients sophisticated dual site solutions for disaster recovery and business continuity.

Capacity and Regional Specialization

The portfolio encompasses nearly 16,000 square meters of raised floor space, supported by more than 30MW of utility power. Each location is tailored to specific industry needs. The London Docklands sites offer ultra low latency proximity for financial trading and legal services, while the Slough and Reading facilities cater to the booming Hi Tech sector along the M4 corridor. This geographical diversity allows businesses to colocate their infrastructure in environments optimized for their specific vertical markets.

Reading Facility Site Security and Risk Mitigation

The Reading data center is housed in a single story steel and brick building specifically chosen for its low risk profile. To ensure maximum uptime, the site is situated outside of known flight paths, flood zones, and away from Control of Major Accident Hazards COMAH sites. Located 22 miles from Heathrow and 37 miles from Central London, it balances accessibility with a safe distance profile, minimizing the impact of urban hazards or environmental threats.

Technical Specifications and Power Density

The Reading facility boasts a total building size of 4,178 square meters, with 3,452 square meters dedicated to functional whitespace. It is engineered for a fully built out power capacity of 4.32 MW, maintaining a power density of 0.175 kW per square meter. The infrastructure is designed to Tier 3 standards, incorporating N plus 1 redundancy across UPS, cooling, and standby power systems to guarantee that mission critical operations remain online during equipment maintenance or failure.

Rigorous Security and Compliance Standards

Security at the Reading site is multilayered, featuring 24/7 onsite staff, mantrap entries, CCTV surveillance, and biometric access controls. The facility adheres to world class compliance frameworks, including ISO27001, SOC 1 and 2 Type II, and DSS PCI certifications. Fire safety is managed through an automatic pre action dry pipe sprinkler system, ensuring that hardware is protected from both fire and accidental water damage, meeting the strict auditing requirements of global enterprises.

Flexible Colocation and Onsite Amenities

Cyxtera offers a versatile range of hosting options, from shared rackspace and partial cabinets to private cages and custom suites. Clients benefit from a Meet Me Room with five peering networks and specialized services like Remote Hands for off site technical support. To facilitate onsite productivity, the center includes professional amenities such as conference rooms, office spaces, breakrooms, and guest WiFi, providing a comprehensive environment for both hardware and the teams that manage it.

Why Choose London Dc 75

London Dc 75 data center is built to meet the demands of modern enterprises, offering robust infrastructure, premium connectivity, and top-tier security. Whether you're deploying a single server or scaling to multiple racks, each facility is engineered for performance, reliability, and flexibility.

Tier III Certified

Redundant infrastructure with 99.99% uptime guarantee

Premium Connectivity

Multiple carrier options and low-latency connections

Advanced Security

Biometric access, 24/7 monitoring, and CCTV surveillance

Prime Location

Central London location with excellent transport links

Expert Support

Local technical team available 24/7 for remote hands

Scalable Solutions

From single rack to private cage configurations

Technical Specifications

Comprehensive infrastructure details for London Dc 75

Total Critical Power

4.32 MW

Indicates the maximum uninterrupted power capacity the facility can support during operation.

Max Power Rack

0.175 KW/sq.m.

Specifies the maximum power allocation per rack, ensuring high-density deployments.

UPS Redundancy

N+1

Ensures continuous power supply via redundant UPS systems in case of failure.

Standby Power Redundancy

N+1

Supports critical systems with backup power sources during outages or maintenance.

Cooling Redundancy

N+1

Maintains optimal temperatures through backup cooling systems.

Automatic Firesuppression

Instantly detects and suppresses fires without manual intervention.

Fire Suppression System

Provides a comprehensive system to control or extinguish fires automatically.

Meet-Me-Room (MMR)

Enables cross-connection between carriers and customers within the facility.

WiFi

On-site wireless connectivity for operational convenience.

Mantrap Entry

Prevents unauthorized access with secure, two-stage entry points.

CCTV Surveillance

Monitors premises in real-time for safety and compliance.

Biometric Access Control

Secures critical areas with fingerprint or retinal scanning systems.

Card Access Control

Allows controlled entry through RFID or magnetic access cards.

Onsite Security Staff

Ensures 24/7 monitoring by trained security personnel.

Total Whitespace

3,452 Sq.m.

Indicates available raised floor space for IT infrastructure.

Total Building Size

4,178 Sq.m

Total structural area of the facility housing all infrastructure.

Roof Access

Facilitates maintenance or antenna installations on the roof.

Conference Room

Dedicated space for meetings, collaboration, and customer use.

Breakroom

Provides a relaxation area for staff and technicians.

Office Space

On-premises workspace for clients or partners.

Crash Cart(s)

Mobile toolkits available for immediate troubleshooting.

Key Performance Metrics

99.99%
Uptime SLA
4.32 MW
Total Power
24/7
Remote Hand Support

Compliance & Certifications

Tier 3
Uptime Institute (Design)
PCI DSS
PCI DSS
Certified
SOC 1
SOC 1
Type II Certified
SOC 2
SOC 2
Type II Certified
ISAE 3402
ISAE 3402
Type II Certified
SSAE 18
SSAE 18
Type I Certified
ISO 27001
ISO 27001
Information Security

Our Colocation Plans

Want to get a custom quote?

Interested in this facility? Reach out to our team for specific pricing and availability.