Units 2 & 3, Pelham Rd, Central Park Dr CV23 0PB Rugby United Kingdom
nLighten (Rugby BHX2)

The Rugby facility is engineered for high performance workloads, featuring a fully built out power capacity of 1.25 MW. It is designed with a Power Usage Effectiveness value of 1.29, reflecting a strong commitment to energy efficiency. To support the diverse needs of its clients, the center offers standard power densities of 2 to 7 kW per rack, with the capability to scale up to 12 kW for high density air cooling or over 50 kW for specialized AI ready rear door cooling configurations.

Workspace and Infrastructure Design

The data center provides a fully built out whitespace of 560 square meters, offering a variety of colocation options including full cabinets, partial cabinets, and shared rackspace footprints. The facility is built to a Tier 3 design standard, ensuring it is concurrently maintainable. This allows any component in the power or cooling distribution path to be removed for maintenance without disrupting ongoing operations.

Connectivity and Location Advantages

Strategically positioned near the M6 motorway and approximately 30 minutes from Birmingham Airport, the center serves as a critical regional telecommunications nexus. It is a carrier neutral facility featuring diverse fiber entry points and dedicated meet me areas. This connectivity enables access to a growing ecosystem of partners and global cloud providers while maintaining ultra low latency for regional data processing.

Security and Access Control

Security is a foundational pillar of the Rugby Data Center, which employs a five lines of defense strategy. The site is ISO27001 certified and protected by continuous CCTV surveillance with full coverage and compliant data storage. Access is strictly managed through dual factor authentication using biometric verification such as fingerprint recognition along with secure card based access control.

Resilience and Environmental Safety

To guarantee operational continuity, the center includes redundant N plus 1 power supplies with independent A and B feeds delivered to every cabinet. These are supported by UPS battery backups and onsite standby generators. Cooling and humidity systems comply with ASHRAE A1 standards to protect sensitive equipment. The facility is also equipped with advanced VESDA early smoke detection and fire suppression systems designed for high density data hall environments.

Support and Onsite Services

Clients at the Rugby site benefit from professional onsite technical staff available during standard business hours, along with dedicated office space for visiting teams. For urgent requirements outside these hours, the facility provides continuous Remote Hands services and a round the clock Network Operations Center. This support structure ensures installations, circuit testing, and troubleshooting are handled efficiently to maintain a service availability level of 99.982 %.

Why Choose Birmingham Dc 2

Birmingham Dc 2 data center is built to meet the demands of modern enterprises, offering robust infrastructure, premium connectivity, and top-tier security. Whether you're deploying a single server or scaling to multiple racks, each facility is engineered for performance, reliability, and flexibility.

Tier III Certified

Redundant infrastructure with 99.99% uptime guarantee

Premium Connectivity

Multiple carrier options and low-latency connections

Advanced Security

Biometric access, 24/7 monitoring, and CCTV surveillance

Prime Location

Central Birmingham location with excellent transport links

Expert Support

Local technical team available 24/7 for remote hands

Scalable Solutions

From single rack to private cage configurations

Technical Specifications

Comprehensive infrastructure details for Birmingham Dc 2

Total Critical Power

1.25 MW

Indicates the maximum uninterrupted power capacity the facility can support during operation.

Max Power Rack

7 KW

Specifies the maximum power allocation per rack, ensuring high-density deployments.

CCTV Surveillance

Monitors premises in real-time for safety and compliance.

Biometric Access Control

Secures critical areas with fingerprint or retinal scanning systems.

Card Access Control

Allows controlled entry through RFID or magnetic access cards.

Total Whitespace

560 Sq.m.

Indicates available raised floor space for IT infrastructure.

Office Space

On-premises workspace for clients or partners.

Onsite Technical Staff

Certified technicians available on-site to assist with technical needs.

Key Performance Metrics

99.99%
Uptime SLA
1.25 MW
Total Power
24/7
Remote Hand Support

Compliance & Certifications

Tier 3
Uptime Institute (Design)
ISO 27001
ISO 27001
Information Security